Más en Dataloggers Anterior Siguiente

30 DAY DISPLAY WITH EXTERNAL PROBE

New, easy to read LCD display with 30 day summary

IVA no incluido



()

  • New, easy to read LCD display with 30 day summary
  • Interchangeable External Probe with high quality gold plated connector.
  • Up to 15,900 recordings – Enough memory for 66 days at 6 minute logging
  • Built-in audible alarm
    Product Model TRED30-16R (Replaceable Battery).
    External Sensor Measurement Range -40°C to +99°C (-40°F to +210°F).
    Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
    Storage Temperature Range -10°C to +40°C (14°F to +104°F).
    Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
    Better than ±0.8°C (±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F).
    Better than ±0.8°C (±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F).
    Better than ±1.2°C (±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F).
    Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
    Accuracy figures can be improved by recalibration.
    Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F).
    0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F).
    0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F).
    0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F).
    Please see the Rated Native Resolution chart below.
    LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
    Sensor Reaction Time Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T, ST100H and ST100S types.
    Recording Capacity 15,905 temperature readings. 66 days @ 6min logging.
    Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics.
    Sampling Interval Configurable from 30 seconds to hourly.
    Logging Start Options Push button start or specific date & time. Optional start delay of up to 18 hours.
    Recording Indication State indicator “RECORDING".
    Download Time Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used.
    Environmental IP61 (when vertically mounted or hung).
    Power Source 3V CR2032 (LiMnO2) coin cell battery, user replaceable.
    Battery Life Typically 1 year of operation.
    NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
    Download data monthly.
    NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.
    Real Time Clock Built-in real time clock.
    Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
    Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
    Standard Remote Sensor Cable Length Standard: 1.5m (4’11").
    Extended: 3m (9’10") (Recommended maximum).
    Remote Sensor Cable Type PTFE (FDA food contact rated), coaxial.
    Size 93mm(H) x 54.5mm(W) x 8.6mm(T).
    Weight 41g.
    Case Material Polycarbonate.

Productos Relacionados

NUESTROS PRODUCTOS