Más en Dataloggers Anterior Siguiente

Dataloger para el registro de temperatura económico

Dataloger para el registro de temperatura económico, extraplano, robusto y de facil cambio de bateria.

IVA no incluido



()

Registrador de datos con sensor de temperatura integrado con capacidad de memoria interna de 16000 datos.
- Margen de temperatura -40°C … +85°C
- Precisión de hasta ±0,5°C
- 16.000 puntos de medición
- Intervalo de medición mínimo de 30 segundos
- Vida útil de la batería de hasta 3 años

Descripción Tamaño
Trix-8 Product Guide 95 Kb. boton descarga
Trix-16 Product Guide 81 Kb. boton descarga
Product Model TRIX-16.
Sensor Measurement Range -40°C to +85°C (-40°F to +185°F)
Operating Temperature Range -40°C to +85°C (-40°F to +185°F).
Storage Temperature Range -30°C to +55°C (-22°F to +131°F).
Rated Temperature Reading Accuracy Better than ±0.5°C for -20°C to +40°C.
Better than ±0.7°C for -30°C to -20°C and +40°C to +60°C.
Better than ±0.8°C for +60°C to +85°C.
Better than ±0.9°C for -40°C to -30°C.
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution Less than 0.1°C for -40°C to +40°C.
Less than 0.2°C for +40°C to +80°C.
Less than 0.4°C for +80°C to +85°C.
Please see the Rated Native Resolution chart below.
LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Sensor Reaction Time Typically less than 5 minutes (T90) in moving air (1m/s).
Recording Capacity 16,159 temperature readings. 112 days @ 10min logging, 168 days @ 15min logging.
Sampling Interval Configurable from 30 seconds to several hours.
Logging Start Options Push button start or specific date & time. Optional start delay of up to 18hours.
Recording Indication Flashing ‘OK’ indicator / flashing ‘ALERT’ indicator.
Download Time Typically less than 10 seconds for full memory (16,159 readings), depending on computer or readout device used.
Environmental IP65 (roughly equivalent to NEMA 4).
Power Source 3V Li-Mg Battery.
Battery Life 2 – 3 years of normal use (based on 15 minute logging, download data monthly).
Real Time Clock Built-in real time clock.
Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
Size 86mm(H) x 54.5mm(W) x 8.6mm(T).
Weight 33g.
Case Material Polycarbonate.