Más en Dataloggers Anterior Siguiente

MULTI-USE WITH 30 DAY DISPLAY

30 day On-screen summary in calendar-like summary.

IVA no incluido



()

  • Up to 7,770 recordings – Enough memory for 53 days at 10min logging or 80 days at 15min logging.
  • Industry best download time – less than 5 seconds for fully memory.
  • Comprehensive customisation options including alert settings, sample interval and trip duration.
    Product Model TRID30-7R (Replaceable Battery).
    TRID30-7F (Fixed Battery).
    Sensor Measurement Range -30°C to +60°C (-40°F to +210°F).
    Operating Temperature Range -30°C to +60°C (-22°F to +140°F).
    Storage Temperature Range -10°C to +40°C  (14°F to +104°F).
    Rated Temperature Reading Accuracy Better than ±0.5°C (±0.9°F) for measurements from -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
    Better than ±0.8°C (±1.5°F) for other measurements – typically ±0.5°C (0.9°F).
    Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart below.
    Accuracy figures can be improved by recalibration.
    Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F).
    0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F).
    Please see the Rated Native Resolution chart below.
    LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
    Sensor Reaction Time Typically less than 5 minutes (T90) in moving air (1m/s) in EN12830:1999.
    Recording Capacity 7,770 temperature readings. 53 days @ 10min logging, 80 days @ 15min logging.
    Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics.
    Sampling Interval Configurable from 1 minute to hourly.
    Logging Start Options Push button start (with configurable start delay from 1 minute to 18 hours) or specific date & time.
    Recording Indication “REC” symbol on LCD
    Download Time Typically less than 5 seconds for full memory (7,770 readings), depending on computer or readout device used.
    Environmental IP65 (roughly equivalent to NEMA 4) when vertically mounted or hung.
    Power Source 3V Li-Mg Battery.
    Battery Life TRID30-7R: Typically 1 year of operation.
    TRID30-7F: Typically 2+ years of operation.
    NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time. Download data monthly.
    Real Time Clock Built-in real time clock.
    Rated accuracy ±25ppm @ 25°C (equivalent to 2.5 seconds/day).
    Rated temperature coefficient is -0.034 ±0.006ppm/°C (I.e typically +/- 0.00294 seconds/day/°C).
    Connection Interface Interface Cradle
    Software LogTag® Analyzer
    Size 93mm(H) x 54.5mm(W) x 8.6mm(T).
    Weight TRID30-7R: 41g.
    TRID30-7F: 43g.
    Case Material Polycarbonate.